Water inlet valve malfunction|Mal funcionamiento de la válvula de entrada de agua

Fix for the error

Disconnect the dishwasher from the mains network to cut off the power supply. Remove both the bottom front access panel and the toe panel. Inspect the wires connected to the water inlet valve. Any loose wires should be reconnected. If damaged, replace the entire cable harness. If all the wiring is in good condition, use a multimeter and test the water inlet valve resistance. The water inlet valve resistance readings should return around 1,400 ohms. If the resistance exceeds the required parameters, replace the water inlet valve. In case the issue persists, replace the main electronic control unit.|Desconecte el lavavajillas de la red de red para cortar la fuente de alimentación. Retire el panel de acceso frontal inferior y el panel de la punta. Inspeccione los cables conectados a la válvula de entrada de agua. Los cables sueltos deben volver a conectarse. Si está dañado, reemplace todo el arnés de cable. Si todo el cableado está en buenas condiciones, use un multímetro y pruebe la resistencia de la válvula de entrada de agua. Las lecturas de resistencia a la válvula de entrada de agua deberían regresar alrededor de 1,400 ohmios. Si la resistencia excede los parámetros requeridos, reemplace la válvula de entrada de agua. En caso de que el problema persista, reemplace la unidad de control electrónico principal.