Error
Thermal sensor malfunction
Solution
1. Disconnect your range from the mains and locate the thermal sensor circuit on the main electronic control unit
2. Test the circuit's resistance
3. The meter should read around 1,080 ohms at room temperature
4. In case the readings deviate for more than 200 ohms, you will have to replace the oven thermal sensor with a new one
5. However, in case the resistance is within the normal parameters, it is the main electronic control unit that needs replacement.
¿Cómo solucionar el código de error F30 y F31 del rango Kenmore?
Obtenga las respuestas a todos los códigos de error en segundos descargando la aplicación SkillCat
Error
Mal funcionamiento del sensor térmico
Solución
1. Desconecte su rango de la red eléctrica y localice el circuito del sensor térmico en la unidad de control electrónico principal
2. Prueba la resistencia del circuito
3. El medidor debe leer alrededor de 1,080 ohmios a temperatura ambiente
4. En caso de que las lecturas se desvíen por más de 200 ohmios, tendrá que reemplazar el sensor térmico del horno con uno nuevo